828/DEA: Shear Modulus During Cure

Measured with an ARES rheometer in torsional rectangular geometry on samples cured various times at 90C.

Reference:

Weeks, T. S.; Adolf, D. B.; McCoy, J. D. Macromolecules 1999; 32: 1918-1922.

Time (hr)Gg (GPa)G∞ (MPa)
41.460.15
51.450.29
51.440.41
60.64
71.330.88
81.301.70
101.222.30
121.202.80
161.054.20
201.034.50
241.005.80
480.937.70